OKOndt GROUP goes on operating for your non-destructive testing needs. Our team works for you to offer the best NDT solutions of top quality, and impeccable services. In September, the group of our experts attended InnoTrans 2024 and could showcase our latest developments to the visitors, as well as discuss current NDT issues and future partnership

Eddy current probes

Angle shaft (L-shaped) ECP:

  • absolute probe built according to the “Bridge” scheme
  • designed for testing of spots with complicated access or parts having protruding elements
  • applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.

Sensing element of eddy-current probe is placed at the angle of 90˚ to the handle axis.


Designation

Tip Ø ‘D’,
mm

Drop length,
mm

Length,
mm

Centre
frequency

Connector

Material

SU200K5A4.5Dx6.4-105 B

4.5

6.4

105

200 kHz

Triax Lemo/Fischer

Fe/NFe

SU500K5A3Dx6.4-105 B

3

6.4

105

500 kHz

Fe/NFe

SU500K5A4.5Dx6.4-105 B

4.5

6.4

105

500 kHz

Fe/NFe

SU500K5A4.5Dx12.7-105 B

4.5

12.7

105

500 kHz

Fe/NFe

SU2М5A2.5Dx2.7-105 B

2.5

2.7

105

2 MHz

NFe

SU2М5A3Dx2.7-105 B

3

2.7

105

2 MHz

NFe

SU2М5A3Dx6.4-105 B

3

6.4

105

2 MHz

NFe

SU2М5A3Dx12.7-105 B

3

12.7

105

2 MHz

NFe

SU6М5A2.5Dx6.4-105 B

2.5

6.4

105

6 MHz

NFe



SU

200K

5A

4.5D

x

6.4

-

105

B(Sh)

1

2

3

4

 

5

 

6

7

 


1. SU – surface probe for surface flaws detection.

2. Probe frequency:

“HZ” designates the Hz range; “К” designates the kHz range; “М” designates the MHz range.

3. Drop angle of a sensing element to the probe axis “5А” is 90˚.

4. Probe tip diameter, mm.

5. Drop length, mm.

6. Probe length, mm. Standard length of 105 mm (4.1") can be changed upon request.

7. Probe type designation: “B”. “B” – Bridge type probe.

Probes of standard type are manufactured unshielded. In case a shielded probe is required, when making an order, please indicate the letters ”Sh” (Shielded) at the end of a designation code.